MICROPROCESSOR BASED FLAME PHOTOMETER
MODEL: CAI-671 & 672
TECHNICAL SPECIFICATIONS: -
- Microprocessor Based with Printer Interface
- Auto Gas Cutoff facility
- Auto Flame Failure Detection
- Five Measurements in Single Aspiration of the sample
- Calibration Curve Programmability Using Maximum of 5 Standard
- Data Processing Through Curve Fitting Techniques- Least Squares, Quadratic
- Multiple Calibration Curves Saving Facility
- Printer Attachment Facility
- Measurement can be done in ppm as well as in meq
- Setup Storage Facility (up to 10 setup files)
- Sample Data Storage Facility
- Direct Results in ppm and meq.
- Useful for both Medical & Soil Testing Applications
Microprocessor Flame Photometers anneurs comes with Flame Failure detection and Auto Gas Cutoff Facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after a few seconds.
Microprocessor Flame Photometer rsas are used for the determination of Sodium, Potassium, Calcium, Lithium & Barium. They use the latest microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. They have soft touch membrane keys for case of operation. The solution is aspirated through an atomizer. Air, sample and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. Radiations from the flame passes through specific narrow band interference filter and pass to the photo-detector. The final results are displayed on the 128 x 64 alphanumerie LCD. The standard model comes with 2 filters (Na, K). Additional filters Ca & Li are optional at extra cost.
A photoelectric flame photometer is a device used in inorganic chemical analysis to determine the concentration of certain metal ions.
| RANGE | General | Serum | Urine | |
| RANGE |
ppm Na: 0-100 ppm K: 0-100 ppm Ca: 0-100 ppm Li: 0-100 ppm Ba: 0-100 ppm |
meq1 Upto 250 meq/l, 1:100 dil Upto 250 meq/1, 1:100 dil Upto 250 meq/1, 1:100 dil Upto 250 meq/1, 1:100 dil |
meq1 Na: 0-200 1:100 dil K: 0-100 1:100 dil Li: 0-2 1:5 dil |
meq/1 Na: 0-250 1:100 dil K: 0-100 1:100 dil Ca: 0-10 1:2 dil |
Sensitivity: General: Na: 0.5 ppm, K: 0.5 ppm, Ca: 15 ppm, Li: 0.5 ppm, Ba: 30 ppm
Filters:Na & K supplied (Ca, Li and Ba are optional at extra cost) {Ba can be factory fitted only)
Resolution:0.1 ppm/0.1 meq
Reproducibility: < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard
Linearity: < 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standard
Curve Fit Accuracy:< 2% of FS
Display: 128x64 Alphanumeric LCD with backlit
Average Time: In-built in software
Flame System: LPG and Dry Oil Free Sir
Detector: Silicon Photodiode
Calibration: Up to 5 Point Calibration with Curve Fitting Software
Gas Control: Adjustable with knobs
Flame Failure: Auto Detection
Gas Cutoff: Automatic
Ignition System: Auto Ignition
Automiser: Axial flow type
Printer: Provision for attachment of dot matrix printer or HP LaserJet/ inkjet (non-windows) printers with USB interface
Power: 230 V ± 10% AC, 50 Hz
Dimensions: 390 x 250 x 220 mm (L x B x H) (Approx.)
Weight:7.5 Kg (Approx.)
COMPRESSOR UNIT
Air Supply: By oil free mini compressor unit with pressure regulator
Combustion Gas: LPG controlled by precision regulator
Power: 230 V ± 10% AC, 50 Hz
Dimensions: 265 x 225 x 110 mm (L x B x H) (Approx.)
Weight: 8 Kg (Approx.)
ACCESSORIES
Power Cord: 1 Unit
AIR PIPE: 1 Unit (Air Tubing with end clamps)
GAS PIPE: 1 Unit
WASTE WATER PIPE: 1 Unit
BEAKER BOX: 1 Unit (Contains 5 Beakers)
CHIMNEY: 1 Unit
INSTRUCTION MANUAL: 1 Unit